Skip to main content

Table 2 Correlation of traditional measures of LV systolic and diastolic function with 6-minute walk distance

From: Longitudinal strain correlates with 6-minute walk distance whereas ejection fraction and diastolic parameters do not

Correlation with 6-minute walk distance

N

Correlation Estimatea

p Valueb

Biplane Ejection Fraction

58

0.21899

0.0986

log E/e’ medial

44

-0.18010

0.2420

log e’ lateral

44

0.09546

0.5377

log e’ medial

46

0.16251

0.2806

log deceleration time

49

0.13687

0.3484

log E

48

-0.00851

0.9542

log A

48

-0.05602

0.7053

log E/A ratio

47

0.04471

0.7654

  1. a. The correlation estimate based on log transformation
  2. b. Significance set at p < 0.05