Table 2 Overview of reproducibility of emerging echocardiographic parameters

From: Transthoracic echocardiographic assessment of ventricular function in functional single ventricle: a comprehensive review

Study

Parameters

Intraobserver variability

Interobserver variability

n

ICC

Categorizationa

n

ICC

Categorizationa

Wilkinson et al[48].

2D-GLS

40

0.93

excellent

40

0.88

good

Tham et al[12].

2D-GLS

2D-GLSR

20

0.81

0.81

good

good

52

0.83

0.93

good

excellent

Colquitt et al[30].

2D-GLS

2D-GLSR

10

0.91

0.80

excellent

good

10

0.85

0.78

good

good

Sato et al[49].

3D-PS

25

0.86

good

25

0.81

good

Sato et al[50].

3D-PS

14

0.95

excellent

14

0.79

good

Chen et al[51].

3D-GLS

3D-GCS

Twist

Torsion

45

0.76

0.84

0.88

0.80

good

good

good

good

45

0.83

0.80

0.87

0.83

good

good

good

good

Bell et al[52].

RT3DE-EF

28

0.92

excellent

28

0.83

good

Soriano et al[53].

RT3DE-EF

7

0.86

good

27

0.75

good

  1. a. Indicator repeatability classification criteria: ICC < 0.5: poor repeatability, 0.5 ≤ ICC < 0.75: moderate repeatability, 0.75 ≤ ICC < 0.9: good repeatability, ICC ≥ 0.9: excellent repeatability [53]
  2. Abbreviations: ICC, intraclass correlation coefficient;2D-GLS, global longitudinal strain measured by two-dimensional speckle tracking imaging;2D-GLSR, global longitudinal strain rate measured by two-dimensional speckle tracking imaging;3D-PS, principal strains measured by three-dimensional speckle tracking imaging; 3D-GLS, global longitudinal strain measured by three-dimensional speckle tracking imaging;3D-GCS, global circumferential strain measured by three-dimensional speckle tracking imaging; RT3DE-EF, ejection fraction measured by real-time three-dimensional echocardiography